Active1 models

PG5900A Series

IEC61850-3 Certified Smart Grid Protocol Gateway

Overview

PG5900A Series The PG5900A Series is a highly reliable and fault tolerant Industrial Protocol Gateway. Its powerful architecture provides seamless conversion between the different Ethernet-based protocols. The IEDs communicating on different protocols could be integrated into the system and extend its reach over the gateway’s redundant Ethernet. This device is designed to work in most demanding industries such as power substations, power generation, oil and gas, farming and manufacturing. The configuration carried out through a user friendly, Java- Based Windows Utility called eNode Designer, that allows configuring target platforms, set device properties and protocol data mapping. The configuration is completely dependent on the “eNode Module” which represents that device or application – but may include things such as changing the communication port settings and defining where data point information enters and leaves the eNode Designer system. PG59XX Series embeds an additional layer of security, allowing the devices to be deployed in topologies that request data to flow through the Internet and preventing sensitive control and monitoring data to be readable from malicious activities. IPsec VPN encryption, configurable in both peer-to-peer and peer-to-side modes will make sure the data passing is encrypted through a strong 128, 192 or 256-bit AES encryption. OpenVPN-based applications can take advantage of Client/Server support on our device. An additional highlight of ATOP protocol gateways is the ability to enable multiple protocols simultaneously. In contrast to conventional gateways, which require predefinition of a single master and slave protocol each, the Full-License model allows users to transform multiple incoming protocols in our protocol base to others com

Review the shared capabilities of the family, then select a model to see the characteristics that distinguish that ordering option.

Specifications

Shared technical capabilities

Specifications shown here apply at family level. Model-specific differences are identified in Models & Ordering.

Supported Functions
• Generic access to the data(Read, Write) • 8 Logical Devices per Port • GOOSE (Generic Object Oriented Substation Event) – a GOOSE message will be generated by the gateway automatically upon event(*) • (*)Being other protocols not Real-Time, there is no guarantee that GOOSE message is gen erated within 1 ms from the event itelf.
Supported Control Type of commands
• Direct-with-Normal-Security Select Before Operate (SBO)-with-Normal-Security • Direct-with-Enhanced Security Select Before Operate (SBO)-with-Enhanced-Security
Implemented Protocol Subsets
• IEC 61850-6 (Substation Configuration Language Description: SCL) • IEC 61850-7-1 (Principles and Models) • IEC 61850-7-2 (Abstract Communication Service • Interface: ACSI • IEC 61850-7-3 (Common Data Classes: CDC) • IEC 61850-7-4 (Logical Nodes and data Object Classes) • IEC 61850-8-1 (Mapping to Manufacturing Message Specification: MMS) • Edition 1 & Edition 2 are both Supported
Supported DNP3 Object Library
• Binary Inputs up to 8000 pts • Binary Outputs up to 2000 pts • Double Inputs up to 4000 pts • Analog Inputs up to 250 pts • Analog Outputs up to 250 pts • Counters up to 250 pts
Supported Function Codes
1: Read Coils 2: Read Discrete Inputs 3: Read Holding Registers 4: Read Input Registers 5: Write Single Coil 6: Write Single Register 15: Write Multiple Coils 16: Write Multiple Registers 43/14: Read Device Identification (server side only)
Supported Exception Codes
1: illegal function 2: illegal data address 3: illegal data value 4: server device failure 6: server device busy
Supported Data Types
• Monitors Points: Each supports maximum 1000 pts: Single Point, Double Point, Step Position, Bit String, Mea sured with Normalized Value, Measured with Scaled Value, Measured Short Floating Points Value, Integrated Totals. • Control Points: Each supports maximum 500 pts: Single Command, Double Command, Regulating Step Command, Set Point Command with Normalized Value, Set Point Command with Scaled Value, Set Point Command Short Floating Point, Bitstring. • Event Logging (Server Side only) Universal Event Buffer up to 20,000 Events
General Specifications
• Serial Mode or Ethernet with TCP or UDP Mode • Server side supports serving up to 5 client in TCP Mode • Client side in a single RS-485 port, supports connecting up to 16 IEDs • Client side supports connecting up to 16 IEDs • Maximum Fragment size 2048 octets • Protocol implementation with configurable parameters conforms to IEEE Std 1815-2012 level 2
IEC 61850-3IEEE 1613FCCRoHS
Applications

Where this family fits

Application statements are derived from approved product literature and require engineering review before publication.

01

Power Substation

The family provides industrial connectivity capabilities for validated power substation requirements.

Explore application
02

Oil & Gas

The family provides industrial connectivity capabilities for validated oil & gas requirements.

Explore application
Models & ordering

Select the exact model

The selector highlights only what changes between variants. Shared specifications remain in the section above.

Selected model

PG5900A

  • Compliant with IEC 61850-3 and IEEE 1613 Power Substation Standards
  • Optional Full-License version for simultaneous transformation of multiple protocols.
  • Isolated redundant power inputs with 24-48 VDC ,100-240 VAC, 100-370 VDC

Confirm the complete ordering code and regional availability with the responsible ATOP advisor.

Documents for PG5900A
Downloads

Documentation validated for this family

Latest versions appear first. Protected engineering evidence requires an approved individual partner account.

Datasheet

No current file published.

Hardware Installation Guide (HIG)

No current file published.

User Manual

No current file published.

Firmware

No current file published.

Software Tools

No current file published.

CAD / STEP / DXF Drawings

Partner access

Sign in with an approved partner account to view available files.

Partner login

Declaration of Conformity

No current file published.

Certificates & Test Reports

Partner access

Sign in with an approved partner account to view available files.

Partner login